• DS200DMCBG1AED DS215DMCBG1AZZ03A (1)_副本

DS200DMCBG1AKG DS215DMCBG1AZZ03A | GE | Output refresh module

¥7,845.00

Module Number: DS215DMCBG1AZZ03A

Product status:  Discontinued

Delivery time:  In stock

Sales country: All over the world

Product situation: Brandnew , one year warranty

Contact me: Sauldcsplc@gmail.com  +8613822101417   SIMON

Have a good day! Thanks for watching my website!

 

Introduced Product:

531X303MCPARG1
531X303MCPBBG1
531X304IBDAMG1
531X304IBDARG1
531X304IBDASG1
F31X303MCPA002/00
F31X304IBDAMG1-006/09

Description

DS200DMCBG1AKG DS215DMCBG1AZZ03A | GE | Output refresh module

  1. .Many products are not yet on the shelves please contact us for more products
  2. .If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation
  3. .We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible

 

The DS200DMCBG1AKG  changes the status of the output terminals based on the content of the output image area. This is the actual output of the PLC.


The above briefly explains the working principle of PLC. Below, we will use an example to explain why writing a ladder diagram program is not suitable for reusing coils. As shown in the figure below, during input sampling, X001=ON, X002=OFF, Y003 ON, Y004=ON in the input image area are actually written into the output image area. But when continuing to execute, due to DS215DMCBG1AZZ03A  =OFF, Y003=OFF, and the result of this subsequent input is written into the output image area, changing the original state of Y003. So during the output refresh stage, the actual external output Y003=OFF and Y004=ON. Many beginners have encountered this problem, why is X001 already closed while Y003 does not output? The logical relationship is incorrect. It is actually caused by the use of double coils.

 

Mailbox:sauldcsplc@gmail.com |DS215DMCBG1AZZ03A
www.abbgedcs.com | Qiming Industrial Automation| Simon +86 13822101417

We may provide the information of this product:
Guidance manual PDF /Datasheet/ Weight/ Size/ Orignal country/ Prodcuct COO & COM & COC
Certificate of conformity / Certificate of Origin / Certificate of Origin /Operation method
Delivery time/ Provide a one-year warranty / Brand New Original Authentic

Reviews

There are no reviews yet.

Be the first to review “DS200DMCBG1AKG DS215DMCBG1AZZ03A | GE | Output refresh module”

Your email address will not be published. Required fields are marked *