PPA322B HIEE300016R2 HIEE400235R1 | ABB | Prime mover speed control system
¥4,588.00
Module Number: PPA322B HIEE300016R2 HIEE400235R1
Product status: Discontinued
Delivery time: In stock
Sales country: All over the world
Product situation: Brandnew , one year warranty
Contact me: Sauldcsplc@gmail.com +8613822101417 SIMON
Have a good day! Thanks for watching my website!
Introduced Product:
1753-L32BBBM-8A
3BHB045647R0003
AO2000 LS25
4104C
5SHY4045L0004
CP471-00
V7768-320001 350-9301007768-320001 A2
3BHE023784R0001
5SHY3545L0014 3BHE019719R0101
5SHY3545L0014 3BHB013085R0001
Description
PPA322B HIEE300016R2 HIEE400235R1 | ABB | Prime mover speed control system
- .Many products are not yet on the shelves please contact us for more products
- .If there is any inconsistency between the product model and the picture on display, the model shall prevail. Contact us for the specific product picture, and we will arrange to take photos in the warehouse for confirmation
- .We have 16 shared warehouses around the world, so please understand that it can sometimes take several hours to accurately return to you. Of course, we will respond to your concerns as soon as possible
Reasons for PPA322B oscillation and loss of step
Based on operating experience, the causes of generator HIEE300016R2 and loss of step are
a) Static stability failure. This often occurs when the operating mode changes, causing the conveying power to exceed the maximum allowable power at that time.
)The impedance between the generator and the power grid suddenly increases. This situation often occurs when a short circuit occurs at a point in the power grid where the generator is connected, and some parallel components are cut off, such as one back circuit in a double circuit line being disconnected, or one parallel transformer being cut off.
The power of the power system suddenly becomes unbalanced. If a large capacity unit suddenly sheds load and a connecting line trips, causing serious power imbalance in the system.
d) Large unit demagnetization. Large unit HIEE300016R2 absorbs a large amount of reactive power from the system, resulting in insufficient reactive power and a significant decrease in system voltage, leading to system instability
e) The speed control system of the prime PPA322B is malfunctioning. The malfunction of the prime mover speed control HIEE400235R1 causes a sudden change in the input torque of the prime mover, resulting in a sudden increase or decrease in power, causing the generator torque to lose balance and causing oscillation
f) When the generator is running, the potential is too low or the power factor is too high.
g) The asynchronous parallel connection between power sources failed to pull in synchronization.
The difference between oscillation caused by single machine out of step and systematic oscillation
a) The meter PPA322B amplitude of the out of step unit is larger than that of other units;
Mailbox:sauldcsplc@gmail.com |PPA322B HIEE300016R2 HIEE400235R1
www.abbgedcs.com | Qiming Industrial Control | Simon +86 13822101417